Origin |
Korea |
Model Number |
P-5C |
Description
The P-5C Particulate Monitor performs continuous, nonextractive mass concentration measurements - simply and reliably in a wide variety of applications.
Single-ended, Self-aligned Instrument
Monuts to standard ASA flange, with no requirements for alignment or opposite wall access, resulting in low installation costs.
Ready to Operate
Complete with internal zero and reference calibrations, purge system, and protective covers. Comes With integral purge system and protective covers. Installs in minutes, Operated and calibrated by non-skilled plant personnel.
Rugged Design
Proven reliability for 20+j years in abrasive and/or corrosive applications.
Meets Regulatory Requirements
Has passed US EPA PS 11 Requirements. Ideal for CAM applications.
Minimal Consumables
Save time, money, and inventry stocking.
Specifications
| MEASUREMENT RANGE |
1-20,000 mg/Actual m³ |
| SCALE RANGES |
Dual ranging, user selectable anywhere within the measurement range. |
| DETECTION LIMIT |
0.5 mg/Am³ |
| STABILITY |
Zero and Span Drift Short Term(2 Hr.) - Less than 1% full scale Long Term(24 Hr.) - Less than 2% full scale |
| RESPONSE TIME |
Approximately 3 seconds |
| CALIBRATION |
Internal system automatically performs a low level(zero) and upscale Span cycle at intervals initiated by internal clock or by external data system command(contact closure). External calibration tube provides traceable values for reference calibrations and instrument audits. |
| AMBIENT TEMPERATURE |
30°C to 55°C |
| PROCESS GAS TEMPERATURE |
To + 260°C standard, to + 375°C with high temperature probe option. |
| PROCESS GAS PRESSURE |
To + 130 mm H2O standard To + 375 mm H2O w/ High volume Purge Blower Option. |
| PROCESS GAS VELOCITY |
Instrument operation is independent of gas velocity. |
| POWER REQUIREMENTS |
110° ± 15 Volts AC, 60 Hz, 6A(220 V, 50 Hz optional) |
| OUTPUT |
4-20 MA, 550 ohms maximum resistance. |
Installation Information
| PIPE SIZE |
Mounts into standard 4"(or larger) pipes |
| MOUNTING FLANGE |
ASA standard 4"(150#) flange (9"OD, with eight, 3/4"diameter bolt holes on 7½" diameter B.C.) |
| PROBE LENGTH |
Distance from mounting flange to center of sampling volume - 18", 36" or 60" standard |
| PHYSICAL DIMENSIONS |
Probe length plus 30½"long x 12½"wide x 18high |
| WEIGHT |
125-140 pounds |
Optional Equipment
- High Pressure purge system : For process gas pressures in excess of +130mm H2O
- High temperature probe option : For temperatures from 260 C up to 375°C maximum
- Output cable : Complete with connector, lengths to 500 feet.
- Plant Air Backup
Warranty Twelve(12) month return-to-factory warranty. Specifications subject to change without notice
 |
| Figure 1. P-5C Dimensions |
 |
| Figure 2. NOTE : Transmitted and Received Light are Coaxial |
 |
| Figure 3. P-5C Axial Response Characteristics |
 |
| Figure 4. P-5C Optics Diagram |
|